Arquitectura, Ingeniería, Gestión Hospitalaria y Sociosanitaria.

 
Olvidé contraseña

Structural Shielding Design and Evaluation for Medical Use of X Rays and Gamma Rays of Energies up to 10 MeV.

 11/04/2011

 Inglés

 NCRP Washington DC

Contactar - hospitecnia
This report of the National Council on Radiation Protection and Measurements, which supersedes NCRP Report No. 34, is concerned with structural shielding design and evaluation for medical installations utilizing x rays and gamma rays of energies up to 10 MeV. The report contains recommendations and technical information as well as a discussion of the various factors which must be considered in the selection of appropriate shielding materials and in the calculation of the barrier thickness. Recent availability of new data used to calculate the shielding requirements has resulted in revision of some of the shielding requirement tables set out in Appendix C. Specific values of the parameters used in the formulation of the tables are explicitly given. The calculational procedures are presented in such a manner as to facilitate their use in deriving customized shielding requirements not to be found in the tables. An adjunct to the report presenting full sized reproductions of the curves for barrier requirements is also an innovation for the NCRP. This report is mainly intended for radiological physicists, radiologists, and regulatory personnel who specialize in radiation protecbon. Sections of the report should be of interest also to architects, hospital administrators, and others who are concerned with the planning of new radiation facilities.

NCRP: National Council on Radiation Protection and Measurements
Scientific Committee:

John P. Kelley, Chairman
Robert O. Gorson
Antolin Raventos
David Keasey, Consultant
Raymon Wu, Consultant
Etiquetas:  Medicina nuclear, radioterapia, protección radiológica, seguridad radiológicaServicios Hospitalarios, Servicios Centrales Diagnóstico y Tratamiento, Radioterapia,

COMENTARIOS

comments image

Se el primero en opinar

Es necesario estar registrado para añadir comentarios

HONEYWELL LIFE SAFETY IBERIA Ackermann-Clino es una marca que afronta los procesos de reorientación y adaptación de los Hospital...

INGÉNIEURS HOSPITALIERS EN FRANCE Fechas del curso:  20/06/2012 - 20/06/2012

banner Hemeroteca Hospitecnia

PULSIOXIMETRO RI-FOX El pulsioxímetro Ri-Fox mide la frecuencia del pulso y la saturación de oxígeno de la sangre de for...Precio: 80€

¿Cuál es el modelo de quirófano que se utiliza actualmente? ¿Y cuáles son sus ventajas e inconvenientes respecto a los demás?